CEPAI GROUP CO.,LTD

Non-fixed Assembly-type Thermocouple WRE-120,WRE-130,WRE-131

The industrial assembly-type thermocouple is used as a sensor to measure temperature, usually matched with display instruments, recording meter and electronic computer. It can directly measure temperature from 0oC to 800oC of liquid, vapor, gas medium and solid surface during various production processes....

Send Inquiry
Product Details

WRE series assembly-type thermocouple

Brief Description

The industrial assembly-type thermocouple is used as a sensor to measure temperature, usually matched with display instruments, recording meter and electronic computer. It can directly measure temperature from 0oC to 800oC of liquid, vapor, gas medium and solid surface during various production processes. In addition, the device has the advantages of simple assembly, convenient replacement, pressure spring type temperature sensing element, good anti-vibration, wide measuring range, high mechanical strength, good pressure durability.

Working principle
 Thermocouple  working principle: two conductors with different components are welded at both  ends to form a loop, measuring temperature directly side is called measurement  side, terminal side is called reference side. When the temperature between  measurement side and reference side has a difference, it will generate heat in  the loop current, then connected to the display instrument, And the instrument  indicates the corresponding temperature value of the thermal electromotive  force generated by the thermocouple. Thermocouple thermoelectric EMF will grow  with the measurement temperature’s growth, The size of the thermal electromotive force is related to the  temperature of both ends. It has nothing to do with the length, diameter of the  thermode.
 Junction box,  protective tube, insulated casing, termals and thermal electodes form a basic  structure of assembly-type thermocouple, with a variety of installation of  fixtures.
 Main technical  parameter
 Temperature measurement  range and tolerance

Thermocouple type

Code

Graduation

Measurement range℃

tolerance△t ℃

Nickel - chromium

WRE

E

0~800

±2.5℃/±0.75%│t│

Thermal response  time
When the  temperature appear step change, the thermocouple output variation is to the  equivalent of 50% of the change, The time required is called the thermal  response time “T”.

The nominal pressure of the thermocouple
Generally  speaking, it is the static outside pressure which the protection tube can  withstand without being broken in the room temperature. In fact, allowing  working pressure is not only related to the protection tube material, the  diameter and wall thickness, it is also related to its structure, the  installation method, the into depth, the measured flow rate to its structure,  the installation method, the into depth, the measured flow rate and the type of  media.
The test voltage of the insulation resistance in room  temperature is DC 500V±50V, The  atmospheric conditions of measuring at the room temperature insulation  resistance is 15~35℃, relative  humidity is 45% and atm pressure is 86~106kPa,


a.For thermocouples  that is longer than 1 meters, the product of the resistance value at ambient-temperature and its length should be not less than 100.

Can be expressed as: Rr. L≧100MΩ.ML>1m

Rr here means the insulation resistance value of the thermocouple at  ambient-temperature, the unit is MΩ.


b.For thermocouple of which the length is equal to/less than 1m small, its ambient temperature  insulation resistance value shall not be less than 100MΩ.

Upper-limit temperature of the insulation resistance
The upper-limit temperature of the insulation resistance for thermocouple should not be less  than the following provisions:

Upper-limit temperature℃

Test temperature t℃

 Resistance value MΩ

100≤tm<300

t=tm

10

300≤tm<500

t=tm

2

500≤tm<850

t=tm

0.5

850≤tm<1000

t=tm

0.08

1000≤tm<1300

t=tm

0.02

tm>1300

t=1300

0.02

Model

WR

Thermocouple

Content

 

Code

Heat probe type

R

Pt-Rh30- Pt-Rh6

P

Pt-Rh 10-Pt

N

Nickel chromium-nickel silicon

M

Nickel chromium nickel silicon - silicon

E

Nickel chromium - nickel copper

C

Copper - Copper - Nickel

F

Iron copper nickel

 

Code

Output signal number

None
     2

single
     double

Code

Fixed device form

 

1
     2
     3
     4
     5
     6
     7

Without fixed device
     Fixed threaded
     Movable flange
     Fixed flange
     Movable flange square
     Fixed thread conical
     Straight pipe joint type

Code

Terminal type

2
     3
     4

Splash proof
     Waterproof type
     Explosion proof type

 

Code

Protection tube diameter

0

Φ16mm

1

Φ25mm

2

Φ16mm

3

Φ20mm

 

If the non-fixed assembly-type thermocouple wre-120,wre-130,wre-131 for sale caters to your requirement, welcome to buy with us. As one of the leading such manufacturers and suppliers in China, we will offer you cheap price and excellent services.